Subscribe for the Newsletter

Mobile Navigation

Making Cell Therapies Manufacturable: The Decisions That Shape Successful Translation

Making Cell Therapies Manufacturable: The Decisions That Shape Successful Translation

Nov 24, 2026PAO-11-26-CL-04

Key Takeaways

  • Translating a research-stage cell therapy into clinical-stage GMP manufacturing requires the preservation of cellular identity, function, and safety as production processes change.

  • Early decisions about cell sources, gene delivery, culture conditions, and equipment can determine whether a therapy is manufacturable at a sustainable cost and without extensive redevelopment.

  • Identifying the steps that drive the most variability, such as gene delivery and starting material, and monitoring cell behavior throughout the process with reliable, well-trended analytical methods helps developers control critical product attributes.

  • Biology-led bioprocessing, which selects and optimizes manufacturing technologies according to the biological requirements of the product, helps preserve therapeutic function and safety while building reproducible processes.

  • iPSC-derived therapies present additional challenges involving cell line selection, differentiation consistency, genomic integrity, and residual pluripotent cells.

The Challenge of Translating Living Therapies

A cell therapy that performs exceptionally well in the laboratory may prove difficult to manufacture consistently, and the changes needed to make it manufacturable may alter the characteristics responsible for its therapeutic activity. This is particularly true for products that pass through multiple complex processing steps, such as isolation, activation, gene modification, and expansion, where small shifts at one stage can compound downstream. It is equally true for dynamic cultures such as stem cells, whose state continues to evolve during expansion and differentiation and is therefore highly sensitive to changes in culture format, scale, or reagents. A system that yields healthy, functional cells at research scale may behave quite differently in a larger manufacturing environment. These challenges raise a fundamental question: how can a research process evolve into a reproducible manufacturing process without compromising the biology that makes the therapy promising?

This question is increasingly consequential as cellular therapies expand into more complex forms of cell engineering and regenerative medicine. Engineered immune cells and genetically modified hematopoietic stem cells (HSC)- and induced pluripotent stem cell (iPSC)-derived therapies each have different manufacturing requirements. Yet they share a common starting point: research protocols designed to establish proof of concept, often relying on research-grade reagents, open manual handling, and small-scale formats chosen for experimental performance. Translating those protocols into good manufacturing practice (GMP) production introduces requirements for consistency, safety, process control, cost of goods, and scalability that frequently demand changes to the original methods.

At NueCell Bio, we approach this challenge through a principle we call "biology-led bioprocessing": selecting and optimizing manufacturing technologies according to the biological requirements of the product, rather than adapting the biology to fit the technology. In practice, this means identifying the cellular characteristics that must be preserved, understanding how processing conditions influence them, and designing manufacturing approaches that support reproducibility without compromising therapeutic function or safety. Addressing these considerations early helps avoid decisions that constrain manufacturing options or require extensive redevelopment later.

Biology-Led Bioprocessing: Preserving the Therapeutic Product

Manufacturing changes can introduce trade-offs that are not apparent from measures of cell yield or productivity alone. These challenges become particularly evident during scale-up, when increasing processing volumes and hold times or introducing different equipment can alter the physical environment and cellular responses, requiring developers to reassess conditions established at laboratory scale.

Manufacturing changes rarely affect every step equally. Some unit operations contribute disproportionately to process variability, and identifying them early allows developers to focus monitoring and control where they matter most. Gene delivery is a clear example. Whether the method is viral or non-viral, it must operate within a “Goldilocks zone”: conditions aggressive enough to achieve efficient, consistent delivery of the genetic cargo but gentle enough to preserve cell health, viability, and subsequent expansion. Pushing for higher delivery efficiency can increase cellular stress and compromise the product, while overly conservative conditions may yield too few modified cells. Because this balance can shift with processing scale, equipment, or input cell quality, gene delivery warrants close in-process monitoring so that changes in efficiency or cell health are detected before they propagate to downstream operations.

Starting material adds a further source of variability, particularly for autologous therapies. Cells collected from individual patients differ in number, composition, activation state, and fitness, often reflecting disease burden and prior treatments, and these differences can carry through manufacturing into the final product. A process that performs well with healthy-donor material may respond differently to cells from heavily pretreated patients. Characterizing the cell state of incoming material and tracking how it relates to process performance and product attributes helps developers distinguish starting-material effects from process variability. The phenotype of the manufactured product has been linked to clinical outcomes,¹ underscoring that consistently measured, biologically meaningful attributes deserve a place in process monitoring.

Biology-led bioprocessing requires sufficient understanding of how manufacturing conditions and starting material influence critical cell attributes to guide process design. Complete knowledge of every biological mechanism or processing variable is neither realistic nor necessary, particularly for emerging modalities. Instead, developers must identify the attributes most consequential to product quality and therapeutic function, assess how manufacturing changes may affect them, and establish appropriate evidence and controls as development progresses.

Designing Manufacturability into Early Development

Manufacturing decisions become more difficult to revisit when their limitations emerge late in development. A cell source, genetic modification strategy, or culture system may support proof-of-concept research but prove unsuitable for reproducible production. Changing these elements after extensive preclinical development can require additional experimentation, analytical characterization, and comparability assessments to establish whether the modified process produces an acceptably comparable product.²

For emerging cell therapies with limited manufacturing precedent, early decisions about starting materials, culture conditions, gene delivery, equipment, expansion, and preservation are particularly consequential. Developers must consider whether research processes can operate under appropriate manufacturing controls and support the intended clinical development program, often while the underlying science and available technologies continue to evolve.

iPSC-derived therapies illustrate these interdependencies. A starting cell line must do more than expand: it must retain the capacity to differentiate efficiently and reproducibly into the intended cell type, and it must scale to the quantities required for the product without losing that differentiation potential or its genomic integrity. Culture conditions that promote rapid growth can favor the selection of genomic variants or erode differentiation capacity over successive passages, and limitations introduced early in these extended workflows may become apparent only during later processing, when they are far more expensive to address.

These challenges favor a concurrent development approach in which biological research, process development, analytical characterization, and manufacturing planning inform one another from the earliest stages, so that attributes such as genomic integrity and differentiation potential are assessed at the scale and passage numbers the product will ultimately require. Integrating these activities allows developers to identify technical risks before research processes become firmly established.³ This does not require commercial-scale optimization during discovery, which would be financially unrealistic and scientifically premature for many emerging biotechnology companies. Instead, developers should prioritize decisions with significant downstream consequences and generate the evidence needed to advance without introducing unnecessary technical or financial risk.

The Additional Manufacturing Challenges of iPSC-Derived Therapies

Induced pluripotent stem cells (iPSCs) offer considerable therapeutic potential because they can expand extensively and differentiate into multiple specialized cell types. Translating these capabilities into reproducible manufacturing, however, involves challenges spanning cell line selection, culture, differentiation, characterization, and product safety. The International Society for Stem Cell Research (ISSCR) addresses these in its 2025 Best Practices for the Development of Pluripotent Stem Cell-Derived Therapies,4 summarized in Stem Cell Reports in 2026.5

Starting Cell Lines and Banking Strategies

For allogeneic products, selecting the starting line is the first critical decision on the path to translation. This requires a formal risk assessment covering donor provenance and consent, derivation records, characterization data, and freedom to operate for reprogramming, editing, and reagent technologies, supported by testing for pluripotency, genomic integrity, identity, and sterility. A line selected primarily for research performance may not meet these requirements.

Allogeneic programs build master and working cell banks to support repeated manufacturing campaigns, while autologous programs require patient-specific iPSC stocks. In both cases, the expansion and banking process, including culture media, matrices, and passaging methods, should be locked before cell banks are produced, since later changes can introduce risks and trigger comparability studies. Raw materials, such as media, growth factors, and matrices, warrant similar risk-based qualification, with clinical-grade materials preferred.

Controlling Differentiation and Scale

iPSCs must retain their pluripotency and genomic integrity through the expansion needed to reach manufacturing scale, while preserving the capacity to differentiate efficiently into the intended cell type. A line may expand well yet differentiate inconsistently, and donor-to-donor and clone-to-clone differences can affect maturation and final product composition even under similar conditions. This is addressed through quality by design: defining a target product profile, identifying critical quality attributes and the process parameters that influence them, and using in-process testing to confirm that differentiation proceeds as intended. Unintended cell types must be characterized to determine whether enrichment is needed.

Genomic Integrity and Product Safety

Reprogramming and prolonged culture can introduce or select genomic alterations, so genomic stability should be assessed at the cell line, bank, and final product stages, informing decisions about culture duration and expansion limits. Residual undifferentiated cells pose a teratoma risk and must be detected with sufficiently sensitive assays and reduced to acceptable levels; proliferative products carry greater risk than post-mitotic ones, and gene-edited products may require deep sequencing or high-resolution genome mapping. Requirements also differ between therapies intended for transient activity and those designed for long-term engraftment.

Demonstrating Functional Maturity and Potency

Achieving the expected cellular identity does not establish that an iPSC-derived product is functional. Some cells must reach a particular maturation state, while others acquire key functions only after administration. Developers therefore need assays that characterize relevant biological functions rather than identity markers alone, with a potency strategy grounded in the mechanism of action and refined as clinical experience accumulates.6 Developers should engage with regulators early to align on product-specific risks and testing strategies.5

Building Analytical Confidence Alongside Process Understanding

Reliable manufacturing decisions depend on analytical methods that accurately capture cellular characteristics and responses to processing conditions. Even established technologies such as flow cytometry and polymerase chain reaction (PCR)-based methods can produce misleading results if reagent variability, instrument performance, procedural differences, or assay drift affect their reliability. Developers must distinguish genuine biological changes from analytical variability before using these measurements to guide process optimization.

At NueCell Bio, we emphasize evaluating method suitability, implementing appropriate controls and reference standards, and tracking and trending assay performance over time. Consistent trending helps identify assay drift caused by changes in reagent lots or other laboratory variables before they influence development decisions. Although analytical qualification requirements evolve with the development stage, methods must be sufficiently reliable for their intended use from the outset.

Equally important is determining which product attributes to measure. Conventional characterization includes identity, purity, viability, and cell number, but these parameters may not always adequately capture therapeutic function. Depending on the modality, developers may also need to assess phenotype, differentiation state, genomic integrity, potency, or other biologically meaningful characteristics. Potency is particularly challenging when cellular products act through multiple mechanisms or interact with host tissues, especially before clinical data establish relationships between measurable attributes and therapeutic outcomes. Early potency strategies must therefore draw on the proposed mechanism of action, using functional assays or scientifically justified surrogate measures that can be refined as evidence accumulates.

The FDA's final guidance on Potency Assurance for Cellular and Gene Therapy Products, issued in November 2026 to replace the agency’s 2011 potency testing guidance, reinforces this approach by recommending an integrated, risk-based strategy encompassing manufacturing controls, in-process testing, and lot-release potency assays.6

Beyond what is measured, when it is measured also matters. Traditional quality control relies largely on snapshots: starting-material specifications, a few in-process checks, and release testing of the final product. These endpoints confirm whether a batch meets its specifications, but they often reveal little about how the cells arrived there, and they may not flag a failing process until it is too late to intervene. New insights are emerging from in-process monitoring that tracks cell behavior throughout manufacturing. Parameters such as growth kinetics, cell size, morphology, intermediate phenotype, and metabolic activity can signal departures from expected behavior well before conventional measurements do.7 Treating the process as a trajectory rather than a series of checkpoints allows developers to recognize emerging variability early, understand its sources, and make informed adjustments while there is still time to act.

Standardizing What Can Be Standardized

Although cell therapies are bespoke, with each product unique in its biology and therapeutic intent, many of the steps used to manufacture them are not. Most processes are built from a common set of unit operations: cell isolation, culture maintenance, washing, gene delivery, expansion, wash and concentration, formulation, and cryopreservation. Many of these can be standardized rather than developed from scratch for each program, so that effort can concentrate on what is truly unique to the product. Leveraging well-characterized operations also shortens timelines and lowers development costs.

Operations differ in how readily they can be standardized. Washing and concentration often rely on similar technologies across different programs, while cryopreservation can draw on common equipment and processing principles, although formulation and operating conditions must still be adapted to the cells. Gene delivery and expansion are more product-specific: finding the balance between efficient delivery and cell health, or between scale and preserved cell state, typically requires tailoring to cell type, genetic cargo, processing scale, and therapeutic objectives.

The value of this approach extends beyond reusing protocols. Hands-on experience with a technology reveals its operating limits, material compatibilities, parameter sensitivities, and failure modes. A method may perform reliably only within a narrow range, or a buffer suitable for one step may impair cell recovery or expansion in the next. Because operations are interdependent, each must also be evaluated in the context of the full process; optimizing one step in isolation can create limitations elsewhere. We draw on experience across technologies and cellular modalities to make these assessments for each sponsor’s process and leverage know-how to inform technology selection and troubleshooting.

This selective approach also sharpens process monitoring. When standardized operations are well characterized, their expected behavior is known, making deviations easier to detect and freeing development effort for the steps most likely to drive variability. When established methods cannot meet a program’s biological or manufacturing requirements, familiarity with alternative and emerging technologies provides the flexibility to find a better fit, keeping the biology, not the technology, at the center of process design. 

Applying the Right Expertise and Rigor at the Right Stage

Preparing a cell therapy for GMP manufacturing requires deciding which uncertainties must be resolved before the next development milestone and which can be managed through continued characterization, appropriate controls, and later optimization. Risks to patient safety, product quality, or manufacturing feasibility demand early attention, but full process optimization is rarely necessary before initial clinical manufacturing. This phase-appropriate approach is consistent with European Medicines Agency guidance for investigational advanced therapy medicinal products.8

For emerging biotechnology companies, prioritization is also a financial necessity. Sponsors must often demonstrate progress toward defined milestones to secure further funding, making it impractical to investigate every potential manufacturing limitation. We therefore begin each engagement by assessing the sponsor's goals, process maturity, and most consequential technical risks and then focus development on the evidence needed to support the next stage.

Technology selection illustrates this balance. Automation and closed processing can improve consistency and efficiency, but adopting them brings its own development burden. For a sponsor approaching a first clinical milestone, a reliable manual process may be the better choice than an automated alternative that requires extensive adaptation. The right decision depends on the product’s biological requirements, technology maturity, available resources, long-term cost of goods, and development objectives. We inform these decisions through internal research, hands-on evaluation of emerging technologies, collaboration with equipment developers, and engagement with scientific and standards organizations.

This kind of translational expertise is most valuable in the gap between discovery and GMP manufacturing. Research teams often know their cells deeply but have limited experience building controlled manufacturing processes. Contract development and manufacturing organizations (CDMOs) bring GMP capabilities, but resolving the uncertainties of an immature research process often calls for a different operating model than routine manufacturing engagements. Translational development bridges the two by combining biological understanding, process engineering, analytical expertise, and practical evaluation of manufacturing technologies.

That bridge must extend through technology transfer. Standard operating procedures and batch records are essential, but the receiving manufacturer also needs to understand process sensitivities, the critical attributes being monitored, the rationale behind key decisions, and any remaining uncertainties. Differences in equipment or scale may require further evaluation during implementation, particularly when full-scale experimentation was impractical earlier in development. For us, technology transfer succeeds when the receiving team can execute the process as intended and reproduce it reliably in its own environment, demonstrating that the knowledge built during development has been translated into practice.

Building a More Effective Path to Clinical Manufacturing

As cell therapies expand into new therapeutic applications, manufacturing approaches must evolve alongside the biology. Each new modality brings its own requirements, but developers should not have to rebuild their understanding of every manufacturing operation from the beginning.

Progress will depend on distinguishing the challenges that arise from a product’s unique biology from those that established processing knowledge, reliable analytical methods, and cross-modality experience can already address. That distinction will matter more as the field moves toward more complex cell populations, engineering strategies, and dynamic cultures, such as stem cell-derived products, where understanding sources of variability and monitoring cell behavior throughout the process become essential.

Meeting these demands will require continued scientific investment, technical flexibility, and close collaboration among researchers, technology developers, translational specialists, and GMP manufacturers. By building on what the field already knows and keeping the biology at the center of process design, the industry can create more effective and cost-efficient manufacturing pathways for an increasingly diverse generation of cellular therapies.

References

1. Budka, Justin, et al. “Determinants of Response to CAR T Cell Therapy in a Multicenter, Multi-Trial Cohort Analysis of Patients with Lymphoma.” Nature Medicine. 23 Oct. 2026.

2. Manufacturing Changes and Comparability for Human Cellular and Gene Therapy Products. Draft Guidance for Industry. U.S. Food and Drug Administration. 13 Jul. 2023.

3. Verbarendse, Maetja, Richard Snyder, and Uma Lakshmipathy. “Mini-Review: Equipment Evaluation for Process Scalability and Readiness for Current Good Manufacturing Practices in Cell Therapy Workflows.” Cytotherapy. 25: 1107–1112 (2023).

4. Best Practices for the Development of Pluripotent Stem Cell-Derived Therapies. International Society for Stem Cell Research. Oct. 2025.

5. Barry, Jaqueline, et al. “Charting the Translational Pathway: ISSCR Best Practices for the Development of PSC-Derived Therapies.” Stem Cell Reports. 21: 102784 (2026).

6. Potency Assurance for Cellular and Gene Therapy Products. Guidance for Industry. U.S. Food and Drug Administration. 2 Nov. 2026.

7. Kebbel, Kati, et al. “Real-World Data from a Single-Center, Large Academic Centralized Manufacturing of CD19 CAR T Cells in an Industry Partnership.” Human Gene Therapy. 37: 802–804 (2026).

8. Guideline on Quality, Non-Clinical and Clinical Requirements for Investigational Advanced Therapy Medicinal Products in Clinical Trials. European Medicines Agency. EMA/CAT/22473/2025. 6 Feb. 2025.